Lightning Surge Arrester for Type 1 and Type 2 Protection

# Lightning Surge Arrester for Type 1 and Type 2 Protection

## Understanding Lightning Surge Arresters

Lightning surge arresters are essential components in protecting electrical systems from the damaging effects of lightning strikes and power surges. These devices work by diverting excess voltage to the ground, preventing it from reaching sensitive equipment. The Type 1+2 Lightning Surge Arrester combines the benefits of both Type 1 and Type 2 protection in a single device.

## Type 1 vs. Type 2 Protection

Type 1 surge arresters are designed to protect against direct lightning strikes, typically installed at the service entrance of a building. They can handle extremely high currents (10/350 μs waveform) and are the first line of defense in a comprehensive surge protection system.

Type 2 surge arresters provide protection against indirect lightning effects and switching surges (8/20 μs waveform). These are usually installed at distribution boards to protect downstream equipment. The combination of Type 1 and Type 2 in a single device offers comprehensive protection from both direct and indirect lightning effects.

## Benefits of Combined Type 1+2 Protection

Space-Saving Solution

The integrated Type 1+2 arrester eliminates the need for separate devices, saving valuable space in electrical panels while maintaining high protection levels.

Cost-Effective Installation

By combining two protection stages in one unit, installation costs are reduced as only one device needs to be mounted and wired.

Seamless Coordination

The coordinated design ensures optimal energy coordination between the protection stages, preventing any gaps in protection.

## Key Features to Look For

  • High discharge capacity (Iimp for Type 1, In for Type 2)
  • Low residual voltage (Up)
  • Visual status indication
  • Thermal disconnection for fail-safe operation
  • Remote signaling capability
  • Robust construction for long service life

## Installation Considerations

Proper installation is crucial for effective surge protection. The Type 1+2 arrester should be installed as close as possible to the service entrance, with short and straight connections to the ground. Follow manufacturer guidelines for:

  • Mounting position and clearances
  • Conductor sizing
  • Grounding requirements
  • Upstream protection

## Maintenance and Testing

While surge arresters are generally maintenance-free, periodic visual inspections are recommended to check for:

  • Status indicators (green/red flags)
  • Physical damage or discoloration
  • Proper connection tightness

Some advanced models feature self-testing capabilities or remote monitoring options for enhanced reliability monitoring.

## Conclusion

The Type 1+2 Lightning Surge Arrester represents an efficient solution for comprehensive surge protection, combining the strengths of both protection classes in a single device. By implementing this technology, facilities can achieve robust protection against both direct lightning strikes and induced surges while optimizing space and installation costs.