BRCB-15/30/40 TP Type 2 Surge Protection Device with Mini Circuit Breaker

,字数在1000字左右

html

BRCB-15/30/40 TP Type 2 Surge Protection Device with Mini Circuit Breaker

In today’s increasingly electrified world, protecting electrical systems from power surges has become more critical than ever. The BRCB-15/30/40 TP Type 2 Surge Protection Device (SPD) combined with a Mini Circuit Breaker offers a comprehensive solution for safeguarding electrical installations against transient overvoltages. This innovative device combines the best of both worlds – superior surge protection and reliable circuit breaking functionality.

Understanding Type 2 Surge Protection

Type 2 surge protection devices are designed to protect electrical installations from indirect lightning strikes and switching transients. The BRCB series represents a significant advancement in this technology by integrating a miniature circuit breaker directly into the SPD unit. This combination provides several distinct advantages over traditional standalone surge protectors.

The Type 2 classification indicates that these devices are intended for installation at the distribution board level, typically as secondary protection following a Type 1 SPD at the service entrance. The BRCB-15/30/40 TP models offer varying levels of protection to suit different installation requirements and risk levels.

Key Features of BRCB Series

The BRCB series stands out with several notable features:

  • Integrated Protection: Combines surge protection and overcurrent protection in a single compact unit
  • Visual Status Indication: Clear indication of protection status and end-of-life warning
  • Thermal Disconnect: Automatic disconnection when the device overheats or reaches end-of-life
  • Compact Design: Space-saving solution that fits standard distribution boards
  • Easy Maintenance: Modular design allows for quick replacement when needed

Technical Specifications

The BRCB series comes in three main variants:

Model Maximum Discharge Current (Imax) Nominal Discharge Current (In) Voltage Protection Level (Up)
BRCB-15 TP 15 kA 7.5 kA ≤ 1.5 kV
BRCB-30 TP 30 kA 15 kA ≤ 1.5 kV
BRCB-40 TP 40 kA 20 kA ≤ 1.5 kV

Installation Considerations

Proper installation is crucial for optimal performance of the BRCB series SPDs. These devices should be installed:

  • At the origin of the electrical installation or sub-distribution boards
  • In parallel with the electrical system being protected
  • With proper earthing connections
  • Following all local electrical codes and regulations

The integrated miniature circuit breaker provides several benefits during installation and operation. It serves as both an overcurrent protection device and a means of dis